Service equipment on how it runs, not on the calendar.
Smart maintenance in BOX2M OS counts what wears your equipment out, such as starts, trips, on-off cycles and hours in operation. When a count passes the limit you set for the day, week or month, the people who act on it get one alert.
Wear shows up as a pattern before it shows up as a breakdown.
Calendars don't know the load
A pump that ran day and night and one that stood idle get the same service date. One is serviced too late, the other too early.
The warning signs are already there
A motor protection that trips again, a compressor that starts every few minutes, a door left open. Each is an alarm on its own, and nobody counts them.
Too many alarms, too little signal
Forty alerts a day about the same compressor get muted. One alert that says "41 starts today" gets read.
Four choices, no data science project.
Smart maintenance is a rule like any other in BOX2M OS. It counts another rule's events instead of a reading.
Pick the event
Any rule you already run, such as a motor trip, a compressor start, a door opening or a device that stops reporting.
Pick what to count
How many times it fired, how many times it cleared, full on-off cycles, or the minutes it stayed active.
Pick the window
Today, this week, this month or last month in the site's time zone, or a rolling window such as the last 24 hours or 15 days.
Set the limit
A fixed number, or a comparison with an earlier period, such as more than three times last month. Alerts go by email, SMS, WhatsApp or voice call, with acknowledgement.
Rules a maintenance team sets up.
- Short cycling: compressor C2 started more than 40 times today
- Service interval: pump P3 ran more than 600 hours this month
- Repeated trips: the motor protection on line 2 tripped 3 times in the last 7 days
- Cold room: the door stayed open more than 90 minutes today
- Connectivity: a gateway went silent more than 5 times this week
- Trend: trips this month are more than three times last month
Example rules. A dry run shows whether a rule would fire now, and why.
Email → maintenance manager
- 11:42C2 started · 38 today
- 12:07Rule triggered · 41 starts today (> 40)
- 12:07WhatsApp and email sent
- 12:31Acknowledged · pressure switch to be checked
What changes for the maintenance team.
Service on usage
Intervals follow run hours, starts and cycles, the way equipment makers specify them, not dates on a calendar.
Fewer breakdowns
Repeated trips, short cycling and rising alarm counts are caught while there is still time to plan the repair.
One alert instead of forty
A pattern raises one message to the people who act on it. Single events stay in the log.
Built on what you already measure
It counts the rules you already run, on the meters, contacts and signals already connected, including devices that stop reporting.
Work orders in your CMMS
An alert can run a playbook that calls your CMMS over HTTP, or your CMMS reads alerts and run-time counters over the API.
Rules your team can read
Every alert says what was counted, in which window and against which limit. Every occurrence stays in the history.
Where it pays first.
Factories and industrial parks
Compressors, pumps, motors and drives, with starts and run hours per machine and shift.
Read moreWhite goods and machinery
Presses, robots and machine tools serviced on the hours they actually ran.
Read morePharma and clinics
Air handlers, chillers and heat pumps, with starts and run hours per unit.
Read moreLogistics and cold rooms
Door openings and compressor starts per cold room, before the temperature drifts.
Read moreTelecom and data infrastructure
Generator starts and run hours, and sites that keep going silent.
Read moreShipbuilding and heavy industry
Cranes, compressors and feeders, with trips and run time per machine.
Read moreQuestions.
Is this predictive maintenance?
It is condition-based maintenance on counts and durations, with rules your team sets and can read. The same history goes to forecasting and predictive tools over the API.
Do we need new sensors?
Not for what is already connected. A run signal, a contact or an energy reading per machine is enough. Where one is missing, we add it as part of the turn-key installation.
Which events can be counted?
Any rule in your account, such as thresholds, deviations, missed readings, devices or circuits that stop reporting, and scheduled checks.
When is a rule checked?
Every time the counted event fires or clears. A rule that should react when a window rolls over, such as "fewer than 10 starts this week", also gets a schedule.
Tell us what wears out first.
A list of the equipment you maintain and how you service it today is enough to start. One of our engineers answers within one business day.